2026/7/7
1. EMC performance: Passed the national standard level four EMC pulse and surge.
2. Suitable for all resistance strain sensors, with 1-4 options available, and can accommodate up to 4 350Ω sensors.
3. Input signal range: 0-30mV.
4. The baud rate and address can be set through the dip switch.
5. Baud rates: 9600bps, 19200bps, 28800bps, 38400bps, 57600bps, 115200bps
6. Verification method: even verification.
7. Slave dialing address: 0-15.
8. Note: The default baud rate at the factory is 9600bps, even parity, and address 0.
9. Installation method: fixed installation through mounting holes or rail installation.
| Technical Parameter | |
| Supply Voltage | 9-36V DC |
| Precision | ≤0.05% FS |
| Nonlinear Correction | Nine segments nonlinear correction optional |
| Display precision | 1/100000 |
| AD sampling rate optional | 10Hz、40Hz、640Hz、1.28kHz |
| Operating Temperature Range | -10~50 ℃ |
| Relative humidity | 10%~90%RH |
| Communication method | RS485 |
| Communication protocol | Modbus RTU |
| Size | 115*90*40mm |
Anhui TianGuang Sensor Co., Ltd. Standard Edition Universal Template Copyright Filing in progressDisclaimer